Application
: Magnetic level switch for alarm, limit and control functions.
Mounting : Side mounting outside the tank.Top mounting directly in
the tank. Horizontal mounting directly in the tank.Flange or thread or
socket welding connections.
Working
parameters
Pressure <200bar
Temperature 60 + 400°C
Fluid specific gravity >0,6 Kg/l
Operation
The buoyancy force of a process liquid moves a float or a displacer.
The shifting of thefloat/displacer moves an attraction sleeve into the
field of the switch magnet, pulling the magnet toward the sleeve and actuating
the switch quickly and reliably.
Features
Field adjustable switching point and differential.
Materials and sizes are related to tank characteristic and working conditions
such as pressure, temperature and type of liquid contained in the tank.
Accessories
Cooling extension for high temperatures (T >150°C)
Certifications
ATEX 94/9/EC PED 97/23/EC RINA
General
catalogue 
 |
Side
mounting in chamber outside the tank.
Side/side connections.
Up to two switching points.
|
|
 |
Side
mounting in chamber outside the tank.
Side/bottom connections.
Up to two switching points. |
|
 |
Top
mounting directly in the tank.
Up to four switching points. |
|
 |
Horizontal
mounting directly in the tank.
Up to two switching points.
|
|
 |
Horizontal
mounting in chamber outside the tank.
Suitable for high pressure.
One switching point. |
|
 |
Housings
General
working conditions : IP67 watertight housingAreas subject to explosion
hazard : E Ex-d IIC T6 IP 67
|
|
|
geen
foto
|
Limit
switch
Standard
execution : SPDT microswitch
Special
executions :
- SPDT microswitch sealed by inert gas
- SPDT microswitch with gold-plated contacts
- SPDT
reed switch cartridge
*All